| 3501 |
KU003501 |
General Supporting Requirements — 29.2 Frequency of Maintenance |
media_required |
| 3502 |
KU003502 |
General Supporting Requirements — 29.3.1.2 Portable equipment and flexible cord sets (extension cords) that remain connected once they are put in place and are not |
media_required |
| 3503 |
KU003503 |
General Supporting Requirements — 29.3.4 Mechanical Servicing |
media_required |
| 3504 |
KU003504 |
General Supporting Requirements — 30.3 shall be performed in accordance with Table 9 |
media_required |
| 3505 |
KU003505 |
General Supporting Requirements — 30.3.1 PV System Visual Inspections No |
no_media_needed |
| 3506 |
KU003506 |
General Supporting Requirements — 30.3.5 PV System Electrical Tests No |
media_required |
| 3507 |
KU003507 |
General Supporting Requirements — 30.4.2* A label that identifies the highest internal dc voltage shall be affixed to combiners, disconnects, and other enclosures |
media_required |
| 3508 |
KU003508 |
General Supporting Requirements — 30.3.1 PV System Visual Inspections No |
media_required |
| 3509 |
KU003509 |
General Supporting Requirements — 30.3.3 Lubrication |
no_media_needed |
| 3510 |
KU003510 |
General Supporting Requirements — 30.4.1* The equipment owner shall ensure that supporting documentation, including the following, is available: • (1) System desi |
media_required |
| 3511 |
KU003511 |
General Supporting Requirements — 30.4.2* A label that identifies the highest internal dc voltage shall be affixed to combiners, disconnects, and other enclosures |
media_required |
| 3512 |
KU003512 |
General Supporting Requirements — 30.3.1 PV System Visual Inspections No |
media_required |
| 3513 |
KU003513 |
General Supporting Requirements — 30.3.5 PV System Electrical Tests No |
media_required |
| 3514 |
KU003514 |
General Supporting Requirements — 31.3.1 Wind Power Electric Systems and Associated Equipment Visual Inspections and Mechanical Tests No |
no_media_needed |
| 3515 |
KU003515 |
General Supporting Requirements — 31.3.5 Wind Power Electric Systems and Associated Equipment Electrical Tests No |
no_media_needed |
| 3516 |
KU003516 |
General Supporting Requirements — 31.3.1 Wind Power Electric Systems and Associated Equipment Visual Inspections and Mechanical Tests No |
no_media_needed |
| 3517 |
KU003517 |
General Supporting Requirements — 32.1.1* This chapter identifies maintenance requirements and applies to all flow and traditional battery energy storage systems |
media_required |
| 3518 |
KU003518 |
General Supporting Requirements — 32.3.1 Battery ESS Visual Inspections No |
no_media_needed |
| 3519 |
KU003519 |
General Supporting Requirements — 32.3.1 Battery ESS Visual Inspections No |
media_required |
| 3520 |
KU003520 |
General Supporting Requirements — 32.4 Documentation |
media_required |
| 3521 |
KU003521 |
General Supporting Requirements — 32.2 Maintenance Intervals Test to be Performed Equipment Condition Assessment Condition 1 Condition 2 Condition 3 Battery pe |
no_media_needed |
| 3522 |
KU003522 |
General Supporting Requirements — 32.3.1 Battery ESS Visual Inspections No |
media_required |
| 3523 |
KU003523 |
General Supporting Requirements — 33.3 shall be performed in accordance with Table 9 |
media_required |
| 3524 |
KU003524 |
General Supporting Requirements — 33.3.1.1 Electric Vehicle Power Transfer System Equipment Visual Inspections No |
no_media_needed |
| 3525 |
KU003525 |
General Supporting Requirements — 33.4.2 The following supporting documentation shall be available for maintenance: • (1) Mechanical drawings (mounting and struc |
media_required |
| 3526 |
KU003526 |
General Supporting Requirements — 33.3.1.1 Electric Vehicle Power Transfer System Equipment Visual Inspections No |
no_media_needed |
| 3527 |
KU003527 |
General Supporting Requirements — 34.1.2 This chapter does not apply to pools, fountains, and similar installations located at one- and two-family dwellings, sto |
media_required |
| 3528 |
KU003528 |
General Supporting Requirements — 34.3.2 Cleaning |
no_media_needed |
| 3529 |
KU003529 |
General Supporting Requirements — 34.3.5 Public Pools, Fountains, and Similar Installation Electrical Tests Test Type* No |
media_required |
| 3530 |
KU003530 |
General Supporting Requirements — 34.3.1 Public Pools, Fountains, and Similar Installation Visual Inspections No |
media_required |
| 3531 |
KU003531 |
General Supporting Requirements — 34.3.4 Public Pools, Fountains, and Similar Installation Mechanical Servicing No |
no_media_needed |
| 3532 |
KU003532 |
General Supporting Requirements — 35.2 Frequency of Maintenance |
media_required |
| 3533 |
KU003533 |
General Supporting Requirements — 35.3.2 Protective Relay Cleaning Test Type* No |
media_required |
| 3534 |
KU003534 |
General Supporting Requirements — 35.3.5 Protective Relay Electrical Tests Test Type* No |
media_required |
| 3535 |
KU003535 |
General Supporting Requirements — 35.3.5 Protective Relay Electrical Tests Test Type* No |
media_required |
| 3536 |
KU003536 |
General Supporting Requirements — 35.3.2 Protective Relay Cleaning Test Type* No |
media_required |
| 3537 |
KU003537 |
General Supporting Requirements — 35.3.5 Protective Relay Electrical Tests Test Type* No |
media_required |
| 3538 |
KU003538 |
General Supporting Requirements — 35.3.5 Protective Relay Electrical Tests Test Type* No |
media_required |
| 3539 |
KU003539 |
General Supporting Requirements — 36.2 Maintenance Intervals Equipment Condition Assessme Battery Technology Test to be Performed Condition 1 Condition 2 Inspe |
media_required |
| 3540 |
KU003540 |
General Supporting Requirements — 36.3.1 Stationary Standby Batteries Visual Inspections No |
no_media_needed |
| 3541 |
KU003541 |
General Supporting Requirements — 36.4 Documentation |
media_required |
| 3542 |
KU003542 |
General Supporting Requirements — 36.2 Maintenance Intervals Equipment Condition Assessme Battery Technology Test to be Performed Condition 1 Condition 2 Vente |
media_required |
| 3543 |
KU003543 |
General Supporting Requirements — 36.3.1 Stationary Standby Batteries Visual Inspections No |
no_media_needed |
| 3544 |
KU003544 |
General Supporting Requirements — 36.3.5 Stationary Standby Battery Electrical Tests No |
media_required |
| 3545 |
KU003545 |
General Supporting Requirements — 39.3.1 Transfer Switch Equipment Visual Inspections Test Type* No |
no_media_needed |
| 3546 |
KU003546 |
General Supporting Requirements — 39.3.1 Transfer Switch Equipment Visual Inspections Test Type* No |
no_media_needed |
| 3547 |
KU003547 |
General Supporting Requirements — 39.3.4 Transfer Switch Mechanical Servicing Test Type* No |
no_media_needed |
| 3548 |
KU003548 |
General Supporting Requirements — 39.3.5 Transfer Switch Equipment Electrical Tests Test Type* No |
media_required |
| 3549 |
KU003549 |
General Supporting Requirements — 39.3.5 Transfer Switch Equipment Electrical Tests Test Type* No |
no_media_needed |
| 3550 |
KU003550 |
General Supporting Requirements — 39.3.1 Transfer Switch Equipment Visual Inspections Test Type* No |
no_media_needed |
| 3551 |
KU003551 |
General Supporting Requirements — 39.3.4 Transfer Switch Mechanical Servicing Test Type* No |
no_media_needed |
| 3552 |
KU003552 |
General Supporting Requirements — 39.3.5 Transfer Switch Equipment Electrical Tests Test Type* No |
media_required |
| 3553 |
KU003553 |
General Supporting Requirements — 3.3.1 Adjustable Speed Drive |
no_media_needed |
| 3554 |
KU003554 |
General Supporting Requirements — 3.3.11.2 Limited Service |
media_required |
| 3555 |
KU003555 |
General Supporting Requirements — Thermal: thermal energy storage • (3) Electrochemical: o (a) Batteries o (b) Flow batteries • (4) Mechanical: o (a) Flyw |
no_media_needed |
| 3556 |
KU003556 |
General Supporting Requirements — 3.3.22 Fault Current, Available (Available Fault Current) |
media_required |
| 3557 |
KU003557 |
General Supporting Requirements — 3.3.22 Available Fault Current |
media_required |
| 3558 |
KU003558 |
General Supporting Requirements — 3.3.28 Ground-Fault Circuit Interrupter, Special Purpose (SPGFCI) |
media_required |
| 3559 |
KU003559 |
General Supporting Requirements — 3.3.50 Reconditioned |
no_media_needed |
| 3560 |
KU003560 |
General Supporting Requirements — 3.3.62.1 Acceptance Tests |
no_media_needed |
| 3561 |
KU003561 |
General Supporting Requirements — 4.7.1 Rework, remanufacturing, or retrofitting of equipment typically involves replacement or refurbishing of major components |
no_media_needed |
| 3562 |
KU003562 |
General Supporting Requirements — 208.85 kPa (30 psi) and the provision of effective chip guarding and appropriate PPE |
media_required |
| 3563 |
KU003563 |
General Supporting Requirements — 5.1.2 Examples of applicable legal regulations include 29 CFR 1926, “Safety and Health Regulations for Construction,” and 29 C |
no_media_needed |
| 3564 |
KU003564 |
General Supporting Requirements — • (3) Load-flow studies • (4) Reliability studies • (5) Incident energy analysis (arc-flash hazard calculations) • (6) M |
media_required |
| 3565 |
KU003565 |
General Supporting Requirements — Overhead line information should include “to” and “from,” connection configuration, nominal voltage, number of lines, li |
no_media_needed |
| 3566 |
KU003566 |
General Supporting Requirements — IEEE is incorporating the information in the color book series into the IEEE 3000 Standards. |
no_media_needed |
| 3567 |
KU003567 |
General Supporting Requirements — The user should refer to the IEEE website (ieee.org) for updated information regarding available standards. |
no_media_needed |
| 3568 |
KU003568 |
General Supporting Requirements — 6.3 shows an example calculation: 500 kVA transformer, 3-phase, 480 volt primary, 208 Y/120 volt secondary, 2 percent Z |
no_media_needed |
| 3569 |
KU003569 |
General Supporting Requirements — 6.5 Load-flow studies show the direction and amount of power flowing from available sources to every load |
no_media_needed |
| 3570 |
KU003570 |
General Supporting Requirements — Some of the events that result in load-flow changes include changing motors, motor horsepower, transformer size, or impe |
media_required |
| 3571 |
KU003571 |
General Supporting Requirements — Reliability of the power source • (3) Equipment selection • (4) Quality of maintenance • (5) Age of equipment • (6) Equi |
media_required |
| 3572 |
KU003572 |
General Supporting Requirements — 6.6 Sample FMEA Table System/Component Failure Mode Frequency per Year Consequence ($1000) Breaker B1 Internal fault 0 |
media_required |
| 3573 |
KU003573 |
General Supporting Requirements — Arc-flash boundary A risk assessment is an important consideration for electrical safe work practices. |
media_required |
| 3574 |
KU003574 |
General Supporting Requirements — Workspaces and systems should be designed to allow safe maintenance or urgent repair while other operations continue. |
no_media_needed |
| 3575 |
KU003575 |
General Supporting Requirements — 6.6 is complete, Annex O of NFPA 70E should be refere |
media_required |
| 3576 |
KU003576 |
General Supporting Requirements — 7.4.4 Circuit loading should not be less than 40 percent of nominal circuit loading |
no_media_needed |
| 3577 |
KU003577 |
General Supporting Requirements — 8.4.3 The test equipment calibration should be traceable to recognized national standards |
media_required |
| 3578 |
KU003578 |
General Supporting Requirements — 9.1.1 The objective of an equipment maintenance program is to maintain safe operation and production while reducing or elimina |
no_media_needed |
| 3579 |
KU003579 |
General Supporting Requirements — Continuous monitoring of specific equipment conditions can be performed using an uninterrupted method of data collection |
media_required |
| 3580 |
KU003580 |
General Supporting Requirements — 9.1.1.3 P–F Curve |
no_media_needed |
| 3581 |
KU003581 |
General Supporting Requirements — • (2) Production personnel thoroughly familiar with the operation capabilities of the equipment and the effect its loss |
no_media_needed |
| 3582 |
KU003582 |
General Supporting Requirements — 9.3.1 Manufacturer’s service manuals and industry standards should have a recommended frequency of inspection |
media_required |
| 3583 |
KU003583 |
General Supporting Requirements — 10.3.2 Examples of ignition sources are |
no_media_needed |
| 3584 |
KU003584 |
General Supporting Requirements — 10.7.2 Damage to factory-installed seals within equipment can necessitate replacing the equipment |
no_media_needed |
| 3585 |
KU003585 |
General Supporting Requirements — 11.3.5 See Table A |
no_media_needed |
| 3586 |
KU003586 |
General Supporting Requirements — Evidence of corona should be documented, and investigation of the root cause and potential for failure should be planned |
media_required |
| 3587 |
KU003587 |
General Supporting Requirements — Equipment enclosures should be inspected for any signs of deterioration, oxidation, impact from environmental factors, l |
no_media_needed |
| 3588 |
KU003588 |
General Supporting Requirements — All enclosures and housings for circuit breakers (switchgear, switchboards, or other) should be inspected and checked fo |
no_media_needed |
| 3589 |
KU003589 |
General Supporting Requirements — • (5) Hidden surfaces such as the adjacent edges between the upper and lower members of split-type bus supports or the e |
media_required |
| 3590 |
KU003590 |
General Supporting Requirements — 12.3.4 Temperatures over design levels for prolonged periods can reduce the electrical life of organic insulating materials |
no_media_needed |
| 3591 |
KU003591 |
General Supporting Requirements — 12.3.5 Online partial discharge (PD) surveys can be performed by permanently installed sensors and PD detection systems or with |
media_required |
| 3592 |
KU003592 |
General Supporting Requirements — 0.635 kV through 38 kV with continuous current ratings above 600 amperes |
media_required |
| 3593 |
KU003593 |
General Supporting Requirements — 14.3.2.1 Where combustible dust is involved, caution should be exercised to ensure that an ignition hazard is not created |
no_media_needed |
| 3594 |
KU003594 |
General Supporting Requirements — 14.3.5 Metal-Enclosed Bus Dielectric Withstand Test Voltages Metal-Enclosed Bus Nominal Voltage (kV, rms) Insulation Withstand |
no_media_needed |
| 3595 |
KU003595 |
General Supporting Requirements — 16.3.5 Fuses can be tested with a continuity tester to verify that the fuse is not open |
no_media_needed |
| 3596 |
KU003596 |
General Supporting Requirements — Cables in vaults should be inspected for sharp bends, physical damage, excessive tension, oil leaks, pits, cable movemen |
media_required |
| 3597 |
KU003597 |
General Supporting Requirements — 20.3.1 Common mode noise voltages can develop when the equipment-grounding conductor and the grounded conductor are not effecti |
no_media_needed |
| 3598 |
KU003598 |
General Supporting Requirements — 20.3.5 An isolation transformer has separate primary and secondary windings |
no_media_needed |
| 3599 |
KU003599 |
General Supporting Requirements — A GFCI disconnects the circuit when a current equal to or higher than the calibration point (4 mA to 6 mA) flows through |
media_required |
| 3600 |
KU003600 |
General Supporting Requirements — 21.3.2 Ground-Fault Sensing and Relaying Equipment |
media_required |