| 3201 |
KU003201 |
General Supporting Requirements — 13.3.5 Panelboard and Switchboard Electrical Testing No |
no_media_needed |
| 3202 |
KU003202 |
General Supporting Requirements — 14.2 Frequency of Maintenance |
media_required |
| 3203 |
KU003203 |
General Supporting Requirements — 14.3.2.2 Compressed air shall not be used to remove dust, dirt, or debris from busways or associated fittings |
no_media_needed |
| 3204 |
KU003204 |
General Supporting Requirements — 14.3.4 Busway Mechanical Servicing Test Type* No |
no_media_needed |
| 3205 |
KU003205 |
General Supporting Requirements — 15.2 Frequency of Maintenance |
media_required |
| 3206 |
KU003206 |
General Supporting Requirements — 15.3.1 MCCB, ICCB, and LVPCB Visual Inspections Test Type* No |
no_media_needed |
| 3207 |
KU003207 |
General Supporting Requirements — 15.3.1 MCCB, ICCB, and LVPCB Visual Inspections Test Type* No |
no_media_needed |
| 3208 |
KU003208 |
General Supporting Requirements — 15.3.3 MCCB, ICCB, and LVPCB Lubrication Test Type* No |
no_media_needed |
| 3209 |
KU003209 |
General Supporting Requirements — 15.3.4 MCCB, ICCB, and LVPCB Mechanical Servicing Test Type* No |
media_required |
| 3210 |
KU003210 |
General Supporting Requirements — 15.3.5 MCCB, ICCB, and LVPCB Electrical Tests Test Type* MCCB† No |
media_required |
| 3211 |
KU003211 |
General Supporting Requirements — 15.4.1 Medium-Voltage Power Circuit Breakers Visual Inspections Test Type* No |
no_media_needed |
| 3212 |
KU003212 |
General Supporting Requirements — 15.4.2 Cleaning |
media_required |
| 3213 |
KU003213 |
General Supporting Requirements — 15.4.3 Medium-Voltage Power Circuit Breakers Lubrication Test Type* No |
no_media_needed |
| 3214 |
KU003214 |
General Supporting Requirements — 15.4.4 Medium-Voltage Power Circuit Breakers Mechanical Servicing Test Type* No |
no_media_needed |
| 3215 |
KU003215 |
General Supporting Requirements — 15.4.5 Medium-Voltage Power Circuit Breakers Electrical Tests Test Type* No |
media_required |
| 3216 |
KU003216 |
General Supporting Requirements — 15.2 Frequency of Maintenance |
media_required |
| 3217 |
KU003217 |
General Supporting Requirements — 15.3.1 MCCB, ICCB, and LVPCB Visual Inspections Test Type* No |
no_media_needed |
| 3218 |
KU003218 |
General Supporting Requirements — 15.3.1 MCCB, ICCB, and LVPCB Visual Inspections Test Type* No |
no_media_needed |
| 3219 |
KU003219 |
General Supporting Requirements — 15.3.2.2 MCCB, ICCB, and LVPCB Cleaning Test Type* No |
no_media_needed |
| 3220 |
KU003220 |
General Supporting Requirements — 15.3.3 MCCB, ICCB, and LVPCB Lubrication Test Type* No |
no_media_needed |
| 3221 |
KU003221 |
General Supporting Requirements — 15.3.4 MCCB, ICCB, and LVPCB Mechanical Servicing Test Type* No |
media_required |
| 3222 |
KU003222 |
General Supporting Requirements — 15.3.5 MCCB, ICCB, and LVPCB Electrical Tests Test Type* MCCB† No |
media_required |
| 3223 |
KU003223 |
General Supporting Requirements — 15.3.5 MCCB, ICCB, and LVPCB Electrical Tests Test Type* MCCB† No |
media_required |
| 3224 |
KU003224 |
General Supporting Requirements — 15.4.1 Medium-Voltage Power Circuit Breakers Visual Inspections Test Type* No |
no_media_needed |
| 3225 |
KU003225 |
General Supporting Requirements — 15.4.1 Medium-Voltage Power Circuit Breakers Visual Inspections Test Type* No |
no_media_needed |
| 3226 |
KU003226 |
General Supporting Requirements — 15.4.2 Medium-Voltage Power Circuit Breakers Cleaning Test Type* No |
no_media_needed |
| 3227 |
KU003227 |
General Supporting Requirements — 15.4.3 Medium-Voltage Power Circuit Breakers Lubrication Test Type* No |
no_media_needed |
| 3228 |
KU003228 |
General Supporting Requirements — 15.4.4 Medium-Voltage Power Circuit Breakers Mechanical Servicing Test Type* No |
no_media_needed |
| 3229 |
KU003229 |
General Supporting Requirements — 15.4.5 Medium-Voltage Power Circuit Breakers Electrical Tests Test Type* No |
media_required |
| 3230 |
KU003230 |
General Supporting Requirements — 15.4.5 Medium-Voltage Power Circuit Breakers Electrical Tests Test Type* No |
no_media_needed |
| 3231 |
KU003231 |
General Supporting Requirements — 16.3 shall be performed in accordance with Table 9 |
media_required |
| 3232 |
KU003232 |
General Supporting Requirements — 16.3.1 Fuse Visual Inspections Test Type* No |
media_required |
| 3233 |
KU003233 |
General Supporting Requirements — 16.3.4 Fuse Mechanical Servicing Test Type* No |
media_required |
| 3234 |
KU003234 |
General Supporting Requirements — 17.2 Frequency of Maintenance |
media_required |
| 3235 |
KU003235 |
General Supporting Requirements — 17.3.1 Switch Visual Inspections Test Type* No |
no_media_needed |
| 3236 |
KU003236 |
General Supporting Requirements — 17.3.2 Switch Cleaning Test Type* No |
no_media_needed |
| 3237 |
KU003237 |
General Supporting Requirements — 17.3.4 Switch Mechanical Servicing Test Type* No |
no_media_needed |
| 3238 |
KU003238 |
General Supporting Requirements — 17.3.4 Switch Mechanical Servicing Test Type* No |
media_required |
| 3239 |
KU003239 |
General Supporting Requirements — 17.3.5 Switch Electrical Tests Test Type* No |
media_required |
| 3240 |
KU003240 |
General Supporting Requirements — 17.3.1 Switch Visual Inspections Test Type* No |
no_media_needed |
| 3241 |
KU003241 |
General Supporting Requirements — 17.3.1 Switch Visual Inspections Test Type* No |
no_media_needed |
| 3242 |
KU003242 |
General Supporting Requirements — 17.3.3 Switch Lubrication Test Type* No |
media_required |
| 3243 |
KU003243 |
General Supporting Requirements — 17.3.4 Switch Mechanical Servicing Test Type* No |
media_required |
| 3244 |
KU003244 |
General Supporting Requirements — 17.3.5 Switch Electrical Tests Test Type* No |
media_required |
| 3245 |
KU003245 |
General Supporting Requirements — 18.1.2 This chapter applies to circuit cables and conductors between the service point or other power supply source and the fin |
media_required |
| 3246 |
KU003246 |
General Supporting Requirements — 18.3.1 Power Cable and Conductor Visual Inspections No |
no_media_needed |
| 3247 |
KU003247 |
General Supporting Requirements — 18.3.5 Power Cable and Conductor Electrical Tests Test Type* No |
media_required |
| 3248 |
KU003248 |
General Supporting Requirements — 19.2 Frequency of Maintenance |
media_required |
| 3249 |
KU003249 |
General Supporting Requirements — 19.3.5 Metal Cable Tray Electrical Tests No |
media_required |
| 3250 |
KU003250 |
General Supporting Requirements — 19.3.5 Metal Cable Tray Electrical Tests No |
media_required |
| 3251 |
KU003251 |
General Supporting Requirements — 20.3.2 Cleaning |
media_required |
| 3252 |
KU003252 |
General Supporting Requirements — 20.3.1 Grounding and Bonding Visual Inspections No |
media_required |
| 3253 |
KU003253 |
General Supporting Requirements — 22.3.5 Electrical Testing |
no_media_needed |
| 3254 |
KU003254 |
General Supporting Requirements — 24.2 Frequency of Maintenance |
media_required |
| 3255 |
KU003255 |
General Supporting Requirements — 24.3.2 Wiring Device Cleaning Test Type* No |
no_media_needed |
| 3256 |
KU003256 |
General Supporting Requirements — 24.3.5 Wiring Device Electrical Tests No |
media_required |
| 3257 |
KU003257 |
General Supporting Requirements — 24.3.1 Wiring Device Visual Inspections No |
no_media_needed |
| 3258 |
KU003258 |
General Supporting Requirements — 24.3.4 Wiring Device Mechanical Servicing No |
media_required |
| 3259 |
KU003259 |
General Supporting Requirements — 25.1.2 This chapter does not apply to a UPS that contains no serviceable components |
media_required |
| 3260 |
KU003260 |
General Supporting Requirements — 25.3.1 UPS Visual Inspections Test Type* No |
no_media_needed |
| 3261 |
KU003261 |
General Supporting Requirements — 25.3.2 UPS Cleaning Test Type* No |
no_media_needed |
| 3262 |
KU003262 |
General Supporting Requirements — 25.3.5 Electrical Testing |
media_required |
| 3263 |
KU003263 |
General Supporting Requirements — 25.3.6.2.1 System Test Conditions |
no_media_needed |
| 3264 |
KU003264 |
General Supporting Requirements — 25.3.6.2.2.3 Any voltage regulation and frequency stability deviations from the manufacturer’s specifications shall be investigated |
no_media_needed |
| 3265 |
KU003265 |
General Supporting Requirements — 25.3.1 UPS Visual Inspections Test Type* No |
no_media_needed |
| 3266 |
KU003266 |
General Supporting Requirements — 25.3.2 UPS Cleaning Test Type* No |
no_media_needed |
| 3267 |
KU003267 |
General Supporting Requirements — 25.3.5 UPS Electrical Tests Test Type* No |
media_required |
| 3268 |
KU003268 |
General Supporting Requirements — 27.2 Frequency of Maintenance |
media_required |
| 3269 |
KU003269 |
General Supporting Requirements — 27.3.1 Rotating Equipment Visual Inspections No |
media_required |
| 3270 |
KU003270 |
General Supporting Requirements — 27.3.4 Mechanical Servicing No |
no_media_needed |
| 3271 |
KU003271 |
General Supporting Requirements — 27.3.5 Rotating Equipment Electrical Tests Test Type* No |
media_required |
| 3272 |
KU003272 |
General Supporting Requirements — 27.3.1 Rotating Equipment Visual Inspections No |
media_required |
| 3273 |
KU003273 |
General Supporting Requirements — 27.3.4 Mechanical Servicing No |
no_media_needed |
| 3274 |
KU003274 |
General Supporting Requirements — 27.3.5 Rotating Equipment Electrical Tests Test Type* No |
media_required |
| 3275 |
KU003275 |
General Supporting Requirements — 28.2 Frequency of Maintenance |
media_required |
| 3276 |
KU003276 |
General Supporting Requirements — 28.3.1 Motor Control Equipment Visual Inspections Test Type* No |
no_media_needed |
| 3277 |
KU003277 |
General Supporting Requirements — 28.3.4 Motor Control Equipment Mechanical Servicing No |
no_media_needed |
| 3278 |
KU003278 |
General Supporting Requirements — 28.3.5 Motor Control Equipment Electrical Tests Test Type* No |
media_required |
| 3279 |
KU003279 |
General Supporting Requirements — 28.3.1 Motor Control Equipment Visual Inspections Test Type* No |
no_media_needed |
| 3280 |
KU003280 |
General Supporting Requirements — 28.3.3 Moving and Sliding Surfaces Lubrication No |
no_media_needed |
| 3281 |
KU003281 |
General Supporting Requirements — 28.3.5 Motor Control Equipment Electrical Tests Test Type* No |
no_media_needed |
| 3282 |
KU003282 |
General Supporting Requirements — 28.3.1 Motor Control Equipment Visual Inspections Test Type* No |
media_required |
| 3283 |
KU003283 |
General Supporting Requirements — 28.3.3 Moving and Sliding Surfaces Lubrication No |
no_media_needed |
| 3284 |
KU003284 |
General Supporting Requirements — 28.3.5 Motor Control Equipment Electrical Tests Test Type* No |
no_media_needed |
| 3285 |
KU003285 |
General Supporting Requirements — 29.2 Frequency of Maintenance |
media_required |
| 3286 |
KU003286 |
General Supporting Requirements — 29.3.1.2 Portable equipment and flexible cord sets (extension cords) that remain connected once they are put in place and are not |
no_media_needed |
| 3287 |
KU003287 |
General Supporting Requirements — 29.3.4 Mechanical Servicing |
media_required |
| 3288 |
KU003288 |
General Supporting Requirements — 30.3 Periodic Maintenance Procedures |
media_required |
| 3289 |
KU003289 |
General Supporting Requirements — 30.3.1 PV System Visual Inspections No |
no_media_needed |
| 3290 |
KU003290 |
General Supporting Requirements — 30.3.5 PV System Electrical Tests No |
media_required |
| 3291 |
KU003291 |
General Supporting Requirements — 30.4.2* A label that identifies the highest internal dc voltage shall be affixed to combiners, disconnects, and other enclosures |
no_media_needed |
| 3292 |
KU003292 |
General Supporting Requirements — 30.3.1 PV System Visual Inspections No |
media_required |
| 3293 |
KU003293 |
General Supporting Requirements — 30.3.5 PV System Electrical Tests No |
media_required |
| 3294 |
KU003294 |
General Supporting Requirements — 31.3.1 Wind Power Electric Systems and Associated Equipment Visual Inspections and Mechanical Tests No |
media_required |
| 3295 |
KU003295 |
General Supporting Requirements — 31.3.5 Wind Power Electric Systems and Associated Equipment Electrical Tests No |
no_media_needed |
| 3296 |
KU003296 |
General Supporting Requirements — 31.3.1 Wind Power Electric Systems and Associated Equipment Visual Inspections and Mechanical Tests No |
media_required |
| 3297 |
KU003297 |
General Supporting Requirements — 31.3.5 Wind Power Electric Systems and Associated Equipment Electrical Tests No |
no_media_needed |
| 3298 |
KU003298 |
General Supporting Requirements — 32.2 Frequency of Maintenance |
media_required |
| 3299 |
KU003299 |
General Supporting Requirements — 32.3.1 Battery ESS Visual Inspections No |
no_media_needed |
| 3300 |
KU003300 |
General Supporting Requirements — 32.3.5 Battery ESS Electrical Tests No |
media_required |