Inspection, Testing, and Maintenance Tasks — 9.3.1 Manufacturer’s service manuals and industry standards should have a recommended frequency of inspection |
media_required |
| 1902 |
KU001902 |
Inspection, Testing, and Maintenance Tasks — 10.3.2 Examples of ignition sources are |
no_media_needed |
| 1903 |
KU001903 |
Inspection, Testing, and Maintenance Tasks — 10.7.2 Damage to factory-installed seals within equipment can necessitate replacing the equipment |
no_media_needed |
| 1904 |
KU001904 |
Inspection, Testing, and Maintenance Tasks — 11.3.5 See Table A |
no_media_needed |
| 1905 |
KU001905 |
Inspection, Testing, and Maintenance Tasks — Evidence of corona should be documented, and investigation of the root cause and potential for failure should be planned |
media_required |
| 1906 |
KU001906 |
Inspection, Testing, and Maintenance Tasks — Equipment enclosures should be inspected for any signs of deterioration, oxidation, impact from environmental factors, l |
no_media_needed |
| 1907 |
KU001907 |
Inspection, Testing, and Maintenance Tasks — All enclosures and housings for circuit breakers (switchgear, switchboards, or other) should be inspected and checked fo |
no_media_needed |
| 1908 |
KU001908 |
Inspection, Testing, and Maintenance Tasks — • (5) Hidden surfaces such as the adjacent edges between the upper and lower members of split-type bus supports or the e |
media_required |
| 1909 |
KU001909 |
Inspection, Testing, and Maintenance Tasks — 12.3.4 Temperatures over design levels for prolonged periods can reduce the electrical life of organic insulating materials |
no_media_needed |
| 1910 |
KU001910 |
Inspection, Testing, and Maintenance Tasks — 12.3.5 Online partial discharge (PD) surveys can be performed by permanently installed sensors and PD detection systems or wi |
media_required |
| 1911 |
KU001911 |
Inspection, Testing, and Maintenance Tasks — 0.635 kV through 38 kV with continuous current ratings above 600 amperes |
media_required |
| 1912 |
KU001912 |
Inspection, Testing, and Maintenance Tasks — 14.3.2.1 Where combustible dust is involved, caution should be exercised to ensure that an ignition hazard is not created |
no_media_needed |
| 1913 |
KU001913 |
Inspection, Testing, and Maintenance Tasks — 14.3.5 Metal-Enclosed Bus Dielectric Withstand Test Voltages Metal-Enclosed Bus Nominal Voltage (kV, rms) Insulation Withstan |
no_media_needed |
| 1914 |
KU001914 |
Inspection, Testing, and Maintenance Tasks — 16.3.5 Fuses can be tested with a continuity tester to verify that the fuse is not open |
no_media_needed |
| 1915 |
KU001915 |
Inspection, Testing, and Maintenance Tasks — Cables in vaults should be inspected for sharp bends, physical damage, excessive tension, oil leaks, pits, cable movemen |
media_required |
| 1916 |
KU001916 |
Inspection, Testing, and Maintenance Tasks — 20.3.1 Common mode noise voltages can develop when the equipment-grounding conductor and the grounded conductor are not effec |
no_media_needed |
| 1917 |
KU001917 |
Inspection, Testing, and Maintenance Tasks — 20.3.5 An isolation transformer has separate primary and secondary windings |
no_media_needed |
| 1918 |
KU001918 |
Inspection, Testing, and Maintenance Tasks — A GFCI disconnects the circuit when a current equal to or higher than the calibration point (4 mA to 6 mA) flows through |
media_required |
| 1919 |
KU001919 |
Inspection, Testing, and Maintenance Tasks — 21.3.2 Ground-Fault Sensing and Relaying Equipment |
media_required |
| 1920 |
KU001920 |
Inspection, Testing, and Maintenance Tasks — Covers and threaded openings should be properly tightened. |
no_media_needed |
| 1921 |
KU001921 |
Inspection, Testing, and Maintenance Tasks — There are two basic types of UPS systems: static and rotary. |
media_required |
| 1922 |
KU001922 |
Inspection, Testing, and Maintenance Tasks — Figure A.25.1.1(b) illustrates a typical multimodule static 3-phase UPS configuration. |
no_media_needed |
| 1923 |
KU001923 |
Inspection, Testing, and Maintenance Tasks — 27.1 Information on generator sets can be found in NFPA 110 |
no_media_needed |
| 1924 |
KU001924 |
Inspection, Testing, and Maintenance Tasks — 27.3.1 Ring Oiling |
media_required |
| 1925 |
KU001925 |
Inspection, Testing, and Maintenance Tasks — 27.3.2.2 One reference for minimum insulation resistance |
media_required |
| 1926 |
KU001926 |
Inspection, Testing, and Maintenance Tasks — recommended by the manufacturer, they should be followed. |
media_required |
| 1927 |
KU001927 |
Inspection, Testing, and Maintenance Tasks — All rotating equipment should be properly aligned at operating temperature when installed. |
media_required |
| 1928 |
KU001928 |
Inspection, Testing, and Maintenance Tasks — Vibration analysis equipment is useful in isolating the source of vibration that might appear to be the result of other |
media_required |
| 1929 |
KU001929 |
Inspection, Testing, and Maintenance Tasks — 27.3.4 Vibration Severity Chart Velocity rms mm/sec in |
no_media_needed |
| 1930 |
KU001930 |
Inspection, Testing, and Maintenance Tasks — building roof or on supports in a ground mounted array. |
no_media_needed |
| 1931 |
KU001931 |
Inspection, Testing, and Maintenance Tasks — 30.3.5 Infrared thermography (IR): This noncontact electrical test can be performed on photovoltaic modules, strings, systems |
media_required |
| 1932 |
KU001932 |
Inspection, Testing, and Maintenance Tasks — 30.4.2 See NFPA 70, Article 690 |
no_media_needed |
| 1933 |
KU001933 |
Inspection, Testing, and Maintenance Tasks — Lead-acid and aqueous alkaline chemistries batteries will emit hydrogen gas; if not vented, the hydrogen concentration w |
no_media_needed |
| 1934 |
KU001934 |
Inspection, Testing, and Maintenance Tasks — ANSI/NETA ATS, Standard for Acceptance Testing Specifications for Electrical Power Equipment and Systems • (2) ANSI/NETA |
no_media_needed |
| 1935 |
KU001935 |
Inspection, Testing, and Maintenance Tasks — A solution of water and bicarbonate of soda (baking soda) can be used to neutralize lead-acid battery spills, and a solu |
no_media_needed |
| 1936 |
KU001936 |
Inspection, Testing, and Maintenance Tasks — 36.3.2 Lead-acid battery surfaces should be cleaned with a solution of water and sodium bicarbonate to avoid leak |
no_media_needed |
| 1937 |
KU001937 |
Inspection, Testing, and Maintenance Tasks — Use of ohmic measurements should be in accordance with the manufacturer’s instructions and with an EMP to set baselines, |
media_required |
| 1938 |
KU001938 |
Inspection, Testing, and Maintenance Tasks — 8.4.1 of NFPA 110 also requires regulated facilities to conduct a monthly EPS exercise under load to test the performance of |
no_media_needed |
| 1939 |
KU001939 |
Inspection, Testing, and Maintenance Tasks — 1.7 Receptacle Outlets |
no_media_needed |
| 1940 |
KU001940 |
Inspection, Testing, and Maintenance Tasks — 1.14 Grouped Electrical Control Equipment (Such as Might Be Mounted on Walls) |
no_media_needed |
| 1941 |
KU001941 |
Inspection, Testing, and Maintenance Tasks — This annex is not a part of the requirements of this NFPA document but is included for informational purposes only. |
media_required |
| 1942 |
KU001942 |
Inspection, Testing, and Maintenance Tasks — Liquid level Circuit Circuit breaker with Normally Normally Disconnect breaker thermal trip open closed rh oti dp typo N |
no_media_needed |
| 1943 |
KU001943 |
Inspection, Testing, and Maintenance Tasks — Figure C.1 Some Typical Electrical Symbols for Power and Control Schematics. |
media_required |
| 1944 |
KU001944 |
Inspection, Testing, and Maintenance Tasks — Normally Normally Normally Normally open-timed closed-timed closed-timed open-timed Normally Normally closed open open c |
no_media_needed |
| 1945 |
KU001945 |
Inspection, Testing, and Maintenance Tasks — Figure C.2 Some Typical Electrical Symbols for Electrical Control Schematic Drawings. |
media_required |
| 1946 |
KU001946 |
Inspection, Testing, and Maintenance Tasks — Rectifier Rectifier diode bridge Thermistor Terminal block . |
no_media_needed |
| 1947 |
KU001947 |
Inspection, Testing, and Maintenance Tasks — Figure C.3 Some Typical Miscellaneous Electrical Symbols. |
no_media_needed |
| 1948 |
KU001948 |
Inspection, Testing, and Maintenance Tasks — 4.16 kV delta to 480Y/277 V wye transformer — kVA _ % impedance Neutral to grounding = electrode _— Amperes continuous _— Amp |
no_media_needed |
| 1949 |
KU001949 |
Inspection, Testing, and Maintenance Tasks — Figure D.1 Typical Use of Symbols in a Single-Line Power Distribution Program. |
no_media_needed |
| 1950 |
KU001950 |
Inspection, Testing, and Maintenance Tasks — Figure D.2 Wiring Diagram for a Reversing Starter with Control Transformer. |
no_media_needed |
| 1951 |
KU001951 |
Inspection, Testing, and Maintenance Tasks — D.3 Figure D.3 shows a power and control schematic for a reversing starter with low-voltage remote pushbuttons. |
media_required |
| 1952 |
KU001952 |
Inspection, Testing, and Maintenance Tasks — WORK ORDER REQUEST Work Order No. |
no_media_needed |
| 1953 |
KU001953 |
Inspection, Testing, and Maintenance Tasks — Figure E.1 Typical Work Order Request Form. |
no_media_needed |
| 1954 |
KU001954 |
Inspection, Testing, and Maintenance Tasks — AIR CIRCUIT BREAKER INSPECTION RECORD Pegs. |
no_media_needed |
| 1955 |
KU001955 |
Inspection, Testing, and Maintenance Tasks — Figure E.2 Typical Air Circuit Breaker Inspection Record. |
no_media_needed |
| 1956 |
KU001956 |
Inspection, Testing, and Maintenance Tasks — AIR CIRCUIT BREAKER TEST AND INSPECTION REPORT Customer Date ——_____________._ Work Order No. |
no_media_needed |
| 1957 |
KU001957 |
Inspection, Testing, and Maintenance Tasks — Figure E.3 Typical Air Circuit Breaker Test and Inspection Report. |
no_media_needed |
| 1958 |
KU001958 |
Inspection, Testing, and Maintenance Tasks — MEDIUM VOLTAGE VACUUM BREAKER SHEETNO. |
no_media_needed |
| 1959 |
KU001959 |
Inspection, Testing, and Maintenance Tasks — Figure E.4 Typical Medium-Voltage Vacuum Breaker Form. |
no_media_needed |
| 1960 |
KU001960 |
Inspection, Testing, and Maintenance Tasks — OIL CIRCUIT BREAKER TEST SHEET NO. |
no_media_needed |
| 1961 |
KU001961 |
Inspection, Testing, and Maintenance Tasks — Figure E.5 Typical Oil Circuit Breaker Test Report. |
media_required |
| 1962 |
KU001962 |
Inspection, Testing, and Maintenance Tasks — DISCONNECT SWITCH TEST REPORT SHEET NO. |
no_media_needed |
| 1963 |
KU001963 |
Inspection, Testing, and Maintenance Tasks — Figure E.6 Typical Disconnect Switch Test Report. |
no_media_needed |
| 1964 |
KU001964 |
Inspection, Testing, and Maintenance Tasks — LOW-VOLTAGE CIRCUIT BREAKER 5-YEAR TESTS FORM Pag] iii Date Substation ——_____________ Feeder ——___________________ Load |
no_media_needed |
| 1965 |
KU001965 |
Inspection, Testing, and Maintenance Tasks — Figure E.7 Typical Low-Voltage Circuit Breaker 5-Year Tests Form. |
no_media_needed |
| 1966 |
KU001966 |
Inspection, Testing, and Maintenance Tasks — ELECTRICAL SWITCHGEAR-ASSOCIATED EQUIPMENT INSPECTION REPORT Plan, Sate, Doeattion, Serial No. |
no_media_needed |
| 1967 |
KU001967 |
Inspection, Testing, and Maintenance Tasks — Figure E.8 Typical Electrical Switchgear–Associated Equipment Inspection Record. |
no_media_needed |
| 1968 |
KU001968 |
Inspection, Testing, and Maintenance Tasks — CURRENT OR POTENTIAL TRANSFORMER RATIO TEST REPORT SHEET NO. |
no_media_needed |
| 1969 |
KU001969 |
Inspection, Testing, and Maintenance Tasks — Figure E.9 Typical Current or Potential Transformer Ratio Test Report. |
no_media_needed |
| 1970 |
KU001970 |
Inspection, Testing, and Maintenance Tasks — OVERLOAD RELAY TEST REPORT SHEETNO. |
no_media_needed |
| 1971 |
KU001971 |
Inspection, Testing, and Maintenance Tasks — Figure E.10 Typical Overload Relay Test Report. |
media_required |
| 1972 |
KU001972 |
Inspection, Testing, and Maintenance Tasks — GROUND FAULT SYSTEM TEST SHEET NO. |
media_required |
| 1973 |
KU001973 |
Inspection, Testing, and Maintenance Tasks — Figure E.11 Typical Ground-Fault System Test Report. |
no_media_needed |
| 1974 |
KU001974 |
Inspection, Testing, and Maintenance Tasks — INSTRUMENT/METER CALIBRATION AND TEST REPORT SHEET NO. |
no_media_needed |
| 1975 |
KU001975 |
Inspection, Testing, and Maintenance Tasks — Figure E.12 Typical Instrument/Meter Calibration and Test Report. |
no_media_needed |
| 1976 |
KU001976 |
Inspection, Testing, and Maintenance Tasks — WATT-HOUR METER TEST SHEET SHEET NO. |
no_media_needed |
| 1977 |
KU001977 |
Inspection, Testing, and Maintenance Tasks — Figure E.13 Typical Watt-Hour Meter Test Sheet. |
no_media_needed |
| 1978 |
KU001978 |
Inspection, Testing, and Maintenance Tasks — PANELBOARD/CIRCUIT BREAKER TEST REPORT SHEET NO. |
no_media_needed |
| 1979 |
KU001979 |
Inspection, Testing, and Maintenance Tasks — Figure E.14 Typical Panelboard/Circuit Breaker Test Report. |
no_media_needed |
| 1980 |
KU001980 |
Inspection, Testing, and Maintenance Tasks — TRANSFORMER TEST AND INSPECTION REPORT SHEET NO. |
no_media_needed |
| 1981 |
KU001981 |
Inspection, Testing, and Maintenance Tasks — Figure E.15 Typical Transformer Test and Inspection Report. |
media_required |
| 1982 |
KU001982 |
Inspection, Testing, and Maintenance Tasks — TRANSFORMER (DRY TYPE) INSPECTION RECORD Pegs. |
no_media_needed |
| 1983 |
KU001983 |
Inspection, Testing, and Maintenance Tasks — Figure E.16 Typical Transformer (Dry Type) Inspection Record. |
no_media_needed |
| 1984 |
KU001984 |
Inspection, Testing, and Maintenance Tasks — TRANSFORMER (LIQUID FILLED) INSPECTION RECORD Paget. |
no_media_needed |
| 1985 |
KU001985 |
Inspection, Testing, and Maintenance Tasks — Figure E.17 Transformer (Liquid Filled) Inspection Record. |
no_media_needed |
| 1986 |
KU001986 |
Inspection, Testing, and Maintenance Tasks — TRANSFORMER OIL SAMPLE REPORT TOTAL NO. |
no_media_needed |
| 1987 |
KU001987 |
Inspection, Testing, and Maintenance Tasks — Figure E.18 Typical Transformer Oil Sample Report. |
no_media_needed |
| 1988 |
KU001988 |
Inspection, Testing, and Maintenance Tasks — 0.03 mgKOH/g MAX |
no_media_needed |
| 1989 |
KU001989 |
Inspection, Testing, and Maintenance Tasks — Figure E.19 Typical Transformer Oil Trending Report. |
no_media_needed |
| 1990 |
KU001990 |
Inspection, Testing, and Maintenance Tasks — TRANSFORMER INSULATION RESISTANCE RECORD Plant) — Date Scope: Power transformers of 150 kVA and greater capacity with pr |
no_media_needed |
| 1991 |
KU001991 |
Inspection, Testing, and Maintenance Tasks — Figure E.20 Typical Transformer Insulation Resistance Record. |
media_required |
| 1992 |
KU001992 |
Inspection, Testing, and Maintenance Tasks — VALVE-REGULATED LEAD-ACID (VRLA) STATIONARY BATTERIES AND CHARGERS INSPECTION REPORT Inspected by; — Inspection date: Us |
media_required |
| 1993 |
KU001993 |
Inspection, Testing, and Maintenance Tasks — VALVE-REGULATED LEAD-ACID (VRLA) MAINTENANCE WORKSHEET BATTERY CHARGE STATUS C1OPEN CIRCUIT FLOAT 1 EQUALIZE BATTERY BUS |
no_media_needed |
| 1994 |
KU001994 |
Inspection, Testing, and Maintenance Tasks — Figure E.21(b) Example of a VRLA Maintenance Worksheet. |
media_required |
| 1995 |
KU001995 |
Inspection, Testing, and Maintenance Tasks — ENGINE GENERATOR INSPECTION SHEET NO. |
no_media_needed |
| 1996 |
KU001996 |
Inspection, Testing, and Maintenance Tasks — Figure E.22 Typical Engine Generator Set Inspection Checklist. |
media_required |
| 1997 |
KU001997 |
Inspection, Testing, and Maintenance Tasks — AUTOMATIC TRANSFER SWITCH SHEET NO.___ oF ____ CUSTOMER DATE PROVECTNO, ADDRESS AIR TEMP, REL, HUMIDITY, OWNERUSER CATE |
no_media_needed |
| 1998 |
KU001998 |
Inspection, Testing, and Maintenance Tasks — Figure E.23 Typical Automatic Transfer Switch Report. |
media_required |
| 1999 |
KU001999 |
Inspection, Testing, and Maintenance Tasks — UNINTERRUPTIBLE POWER SUPPLY (UPS) SYSTEM INSPECTION CHECKLIST For use of this form see TM 5-694: the proponent agency i |
media_required |
| 2000 |
KU002000 |
Inspection, Testing, and Maintenance Tasks — Figure E.24 Typical Uninterruptible Power Supply System Inspection Checklist. |