NFPA 70B — Chapter 10

#KUTitleStatus
901 KU000901 Electrical Maintenance Program Concepts — 35.3.2 Protective Relay Cleaning Test Type* No media_required
902 KU000902 Electrical Maintenance Program Concepts — 35.3.5 Protective Relay Electrical Tests Test Type* No media_required
903 KU000903 Electrical Maintenance Program Concepts — 35.3.5 Protective Relay Electrical Tests Test Type* No media_required
904 KU000904 Electrical Maintenance Program Concepts — 36.2 Maintenance Intervals Equipment Condition Assessme Battery Technology Test to be Performed Condition 1 Condition 2 Perfo media_required
905 KU000905 Electrical Maintenance Program Concepts — 36.3.1 Stationary Standby Batteries Visual Inspections No media_required
906 KU000906 Electrical Maintenance Program Concepts — 36.3.5 Stationary Standby Battery Electrical Tests No media_required
907 KU000907 Electrical Maintenance Program Concepts — 36.2 Maintenance Intervals Equipment Condition Assessme Battery Technology Test to be Performed Condition 1 Condition 2 Vente no_media_needed
908 KU000908 Electrical Maintenance Program Concepts — 36.3.1 Stationary Standby Batteries Visual Inspections No media_required
909 KU000909 Electrical Maintenance Program Concepts — 36.3.5 Stationary Standby Battery Electrical Tests No media_required
910 KU000910 Electrical Maintenance Program Concepts — 39.3.1 Transfer Switch Equipment Visual Inspections Test Type* No no_media_needed
911 KU000911 Electrical Maintenance Program Concepts — 39.3.3 Transfer Switch Equipment Lubrication Test Type* No no_media_needed
912 KU000912 Electrical Maintenance Program Concepts — 39.3.5 Transfer Switch Equipment Electrical Tests Test Type* No no_media_needed
913 KU000913 Electrical Maintenance Program Concepts — 39.3.5 Transfer Switch Equipment Electrical Tests Test Type* No no_media_needed
914 KU000914 Electrical Maintenance Program Concepts — 39.3.1 Transfer Switch Equipment Visual Inspections Test Type* No no_media_needed
915 KU000915 Electrical Maintenance Program Concepts — 39.3.4 Transfer Switch Mechanical Servicing Test Type* No media_required
916 KU000916 Electrical Maintenance Program Concepts — 39.3.5 Transfer Switch Equipment Electrical Tests Test Type* No no_media_needed
917 KU000917 Electrical Maintenance Program Concepts — 1.3.2 Consumer appliances and equipment intended primarily for use in the home are not covered no_media_needed
918 KU000918 Electrical Maintenance Program Concepts — 2.2 NFPA Publications no_media_needed
919 KU000919 Electrical Maintenance Program Concepts — 3.1.3 Merriam-Webster’s Collegiate Dictionary, 11th edition, shall be the source for the ordinarily accepted meaning no_media_needed
920 KU000920 Electrical Maintenance Program Concepts — 3.3.1* Adjustable Speed Drive media_required
921 KU000921 Electrical Maintenance Program Concepts — 3.3.11.2* Limited Service no_media_needed
922 KU000922 Electrical Maintenance Program Concepts — 3.3.22* Fault Current, Available (Available Fault Current) media_required
923 KU000923 Electrical Maintenance Program Concepts — 3.3.33 Grounding Electrode System no_media_needed
924 KU000924 Electrical Maintenance Program Concepts — 3.3.45 Panelboard media_required
925 KU000925 Electrical Maintenance Program Concepts — 3.3.54* Servicing media_required
926 KU000926 Electrical Maintenance Program Concepts — 3.3.62.3 As-Left Tests no_media_needed
927 KU000927 Electrical Maintenance Program Concepts — 4.2 Electrical Maintenance Program (EMP) no_media_needed
928 KU000928 Electrical Maintenance Program Concepts — Identification of personnel responsible for implementing each element of the program • (4) Survey and analysis of equipm media_required
929 KU000929 Electrical Maintenance Program Concepts — 4.2.5 EMP Controls no_media_needed
930 KU000930 Electrical Maintenance Program Concepts — 4.3.3.2 The employer shall determine through regular supervision or through inspections conducted on at least an annual basis th media_required
931 KU000931 Electrical Maintenance Program Concepts — 4.3.3.4 Training shall be documented in accordance with the following: • (1) Documentation shall be issued when the person demon media_required
932 KU000932 Electrical Maintenance Program Concepts — 4.6 Acceptance Test Report no_media_needed
933 KU000933 Electrical Maintenance Program Concepts — 4.7.2 Refurbished or remanufactured equipment shall be marked to identify it as such no_media_needed
934 KU000934 Electrical Maintenance Program Concepts — 5.1 Introduction media_required
935 KU000935 Electrical Maintenance Program Concepts — 6.3.2 The short-circuit study shall be updated when changes occur in the electrical distribution system that could affect the media_required
936 KU000936 Electrical Maintenance Program Concepts — 6.6* Reliability Studies no_media_needed
937 KU000937 Electrical Maintenance Program Concepts — 7.2.1.1 through 7 media_required
938 KU000938 Electrical Maintenance Program Concepts — 1.0 370 Notes: (1) This table is based on national coarse thread pitch no_media_needed
939 KU000939 Electrical Maintenance Program Concepts — 7.2.1.4.3 Torque values for metric fasteners shall comply with the manufacturer’s instructions no_media_needed
940 KU000940 Electrical Maintenance Program Concepts — 7.4 Infrared Thermography media_required
941 KU000941 Electrical Maintenance Program Concepts — 7.4.2* All accessible and necessary covers shall be removed prior to infrared thermography inspection to provide a clear line o media_required
942 KU000942 Electrical Maintenance Program Concepts — Table 7.2.1.4.2(a) Bolt-Torque Values for Electrical Connections, US Standard Fasteners — Cadmium or Zinc Plated Bolt Di no_media_needed
943 KU000943 Electrical Maintenance Program Concepts — 8.1 Introduction no_media_needed
944 KU000944 Electrical Maintenance Program Concepts — o (b) Overpotential • (2) Mechanical, as follows: o (a) Stored energy o (b) Mass energy • (3) Chemical, as follows: o (a no_media_needed
945 KU000945 Electrical Maintenance Program Concepts — 8.3* Testing Category Types media_required
946 KU000946 Electrical Maintenance Program Concepts — 8.3.1 Category 1 — Online Standard Test no_media_needed
947 KU000947 Electrical Maintenance Program Concepts — 8.5 Test Record no_media_needed
948 KU000948 Electrical Maintenance Program Concepts — 8.6 Condition of Maintenance no_media_needed
949 KU000949 Electrical Maintenance Program Concepts — 9.3.2 and the equipment condition assessment, this frequency shall be followed for at least two maintenance intervals unless u no_media_needed
950 KU000950 Electrical Maintenance Program Concepts — 9.2.1.2 Equipment Physical Condition 2 shall be assigned where both the criteria from 9 no_media_needed
951 KU000951 Electrical Maintenance Program Concepts — 9.2.1.4 Management of Nonserviceable Equipment no_media_needed
952 KU000952 Electrical Maintenance Program Concepts — 9.3 Frequency of Maintenance media_required
953 KU000953 Electrical Maintenance Program Concepts — 9.3.2 Maintenance Intervals Equipment Condition Assessment Product Scope of Work Condition 1 Condition 2 Condition 3 Mechanica media_required
954 KU000954 Electrical Maintenance Program Concepts — 9.3.2 Maintenance Intervals Equipment Condition Assessment Product Scope of Work Condition 1 Condition 2 Condition 3 Cleaning no_media_needed
955 KU000955 Electrical Maintenance Program Concepts — 9.3.2 Maintenance Intervals Equipment Condition Assessment Product Scope of Work Condition 1 Condition 2 Condition 3 Protectiv media_required
956 KU000956 Electrical Maintenance Program Concepts — 9.3.2 Maintenance Intervals Equipment Condition Assessment Product Scope of Work Condition 1 Condition 2 Condition 3 Lubricati no_media_needed
957 KU000957 Electrical Maintenance Program Concepts — 9.4.2 The severity of the defect and physical condition of the equipment shall be considered for the time interval that a requ media_required
958 KU000958 Electrical Maintenance Program Concepts — 9.3.2 Maintenance Intervals Equipment Condition Assessment Product Scope of Work Condition 1 Condition 2 Condition 3 Electrica media_required
959 KU000959 Electrical Maintenance Program Concepts — 9.3.2 Maintenance Intervals Equipment Condition Assessment Product Scope of Work Condition 1 Condition 2 Condition 3 Lubricati no_media_needed
960 KU000960 Electrical Maintenance Program Concepts — 9.3.2 Maintenance Intervals Equipment Condition Assessment Product Scope of Work Condition 1 Condition 2 Condition 3 Protectiv media_required
961 KU000961 Electrical Maintenance Program Concepts — 9.3.2 Maintenance Intervals Equipment Condition Assessment Product Scope of Work Condition 1 Condition 2 Condition 3 Mechanica no_media_needed
962 KU000962 Electrical Maintenance Program Concepts — 9.3.2 Maintenance Intervals Equipment Condition Assessment Product Scope of Work Condition 1 Condition 2 Condition 3 Electrica media_required
963 KU000963 Electrical Maintenance Program Concepts — 9.3.2 Maintenance Intervals Equipment Condition Assessment Product Scope of Work Condition 1 Condition 2 Condition 3 Medium-vo no_media_needed
964 KU000964 Electrical Maintenance Program Concepts — 9.3.2 Maintenance Intervals Equipment Condition Assessment Product Scope of Work Condition 1 Condition 2 Condition 3 Power and media_required
965 KU000965 Electrical Maintenance Program Concepts — 9.3.2 Maintenance Intervals Equipment Condition Assessment Product Scope of Work Condition 1 Condition 2 Condition 3 Substatio media_required
966 KU000966 Electrical Maintenance Program Concepts — 9.3.2 Maintenance Intervals Equipment Condition Assessment Product Scope of Work Condition 1 Condition 2 Condition 3 Mechanica no_media_needed
967 KU000967 Electrical Maintenance Program Concepts — 10.3.2* Qualified persons shall be trained to evaluate and eliminate ignition sources and to identify the need for special tools media_required
968 KU000968 Electrical Maintenance Program Concepts — 10.6.2 Covers shall not be interchanged unless identified for the purpose no_media_needed
969 KU000969 Electrical Maintenance Program Concepts — 10.10* Field Modifications media_required
970 KU000970 Electrical Maintenance Program Concepts — 11.3.1 Transformer Visual Inspections Test Type* Dry Type, Air-Cooled No no_media_needed
971 KU000971 Electrical Maintenance Program Concepts — 11.3.2.2 Transformer bushings and any accessible insulators and conductors shall be wiped clean to remove surface buildup of con no_media_needed
972 KU000972 Electrical Maintenance Program Concepts — 11.3.5 Transformer Electrical Tests Test Type* Dry Type, Air-Cooled No media_required
973 KU000973 Electrical Maintenance Program Concepts — 11.3.5 Transformer Electrical Tests Test Type* Dry Type, Air-Cooled No no_media_needed
974 KU000974 Electrical Maintenance Program Concepts — 12.1.1 This chapter identifies maintenance requirements for substations, switchgear, and surrounding areas, whether fenced or i media_required
975 KU000975 Electrical Maintenance Program Concepts — 12.3.1 Substation and Switchgear Visual Inspections Test Type* No media_required
976 KU000976 Electrical Maintenance Program Concepts — 12.3.4* Mechanical Servicing no_media_needed
977 KU000977 Electrical Maintenance Program Concepts — 12.3.5 Substation and Switchgear Electrical Tests Test Type* No media_required
978 KU000978 Electrical Maintenance Program Concepts — 12.3.6.1 Miscellaneous Equipment no_media_needed
979 KU000979 Electrical Maintenance Program Concepts — 12.3.1 Substation and Switchgear Visual Inspections Test Type* No no_media_needed
980 KU000980 Electrical Maintenance Program Concepts — 12.3.4 Substation and Switchgear Mechanical Servicing Test Type* No no_media_needed
981 KU000981 Electrical Maintenance Program Concepts — 12.3.5 Substation and Switchgear Electrical Tests Test Type* No media_required
982 KU000982 Electrical Maintenance Program Concepts — 13.1.1 This chapter identifies maintenance requirements for panelboards and switchboards rated 1000 V or below media_required
983 KU000983 Electrical Maintenance Program Concepts — 13.3.1 Panelboard and Switchboard Visual Inspections No no_media_needed
984 KU000984 Electrical Maintenance Program Concepts — 13.3.4 Panelboard and Switchboard Mechanical Servicing No no_media_needed
985 KU000985 Electrical Maintenance Program Concepts — 13.3.5 Panelboard and Switchboard Electrical Testing No media_required
986 KU000986 Electrical Maintenance Program Concepts — 13.3.1 Panelboard and Switchboard Visual Inspections No no_media_needed
987 KU000987 Electrical Maintenance Program Concepts — 13.3.4 Panelboard and Switchboard Mechanical Servicing No no_media_needed
988 KU000988 Electrical Maintenance Program Concepts — 13.3.5 Panelboard and Switchboard Electrical Testing No media_required
989 KU000989 Electrical Maintenance Program Concepts — 14.3.1 Busway Visual Inspections Test Type* No no_media_needed
990 KU000990 Electrical Maintenance Program Concepts — 14.3.4 Busway Mechanical Servicing Test Type* No no_media_needed
991 KU000991 Electrical Maintenance Program Concepts — 14.3.5 Busway Electrical Tests Test Type* No no_media_needed
992 KU000992 Electrical Maintenance Program Concepts — 14.3.1 Busway Visual Inspections Test Type* No no_media_needed
993 KU000993 Electrical Maintenance Program Concepts — 14.3.5 Busway Electrical Tests Test Type* No no_media_needed
994 KU000994 Electrical Maintenance Program Concepts — 15.2 Frequency of Maintenance media_required
995 KU000995 Electrical Maintenance Program Concepts — 15.3.1 MCCB, ICCB, and LVPCB Visual Inspections Test Type* No media_required
996 KU000996 Electrical Maintenance Program Concepts — 15.3.2.2 MCCB, ICCB, and LVPCB Cleaning Test Type* No no_media_needed
997 KU000997 Electrical Maintenance Program Concepts — 15.3.4 MCCB, ICCB, and LVPCB Mechanical Servicing Test Type* No no_media_needed
998 KU000998 Electrical Maintenance Program Concepts — 15.3.5 MCCB, ICCB, and LVPCB Electrical Tests Test Type* MCCB† No media_required
999 KU000999 Electrical Maintenance Program Concepts — 15.4.1 Medium-Voltage Power Circuit Breakers Visual Inspections Test Type* No no_media_needed
1000 KU001000 Electrical Maintenance Program Concepts — 15.4.1 Medium-Voltage Power Circuit Breakers Visual Inspections Test Type* No no_media_needed