| 301 |
KU000301 |
Administration, Scope, and Application — 17.3.4 Switch Mechanical Servicing Test Type* No |
media_required |
| 302 |
KU000302 |
Administration, Scope, and Application — 17.3.5 Switch Electrical Tests Test Type* No |
media_required |
| 303 |
KU000303 |
Administration, Scope, and Application — 17.3.5 Switch Electrical Tests Test Type* No |
no_media_needed |
| 304 |
KU000304 |
Administration, Scope, and Application — 17.3.1 Switch Visual Inspections Test Type* No |
no_media_needed |
| 305 |
KU000305 |
Administration, Scope, and Application — 17.3.2 Switch Cleaning Test Type* No |
no_media_needed |
| 306 |
KU000306 |
Administration, Scope, and Application — 17.3.4 Switch Mechanical Servicing Test Type* No |
no_media_needed |
| 307 |
KU000307 |
Administration, Scope, and Application — 17.3.5 Switch Electrical Tests Test Type* No |
media_required |
| 308 |
KU000308 |
Administration, Scope, and Application — 17.3.5 Switch Electrical Tests Test Type* No |
no_media_needed |
| 309 |
KU000309 |
Administration, Scope, and Application — 18.2 Frequency of Maintenance |
media_required |
| 310 |
KU000310 |
Administration, Scope, and Application — 18.3.1 Power Cable and Conductor Visual Inspections No |
no_media_needed |
| 311 |
KU000311 |
Administration, Scope, and Application — 18.3.5 Power Cable and Conductor Electrical Tests Test Type* No |
media_required |
| 312 |
KU000312 |
Administration, Scope, and Application — 18.3.1 Power Cable and Conductor Visual Inspections No |
no_media_needed |
| 313 |
KU000313 |
Administration, Scope, and Application — 18.3.1 Power Cable and Conductor Visual Inspections No |
no_media_needed |
| 314 |
KU000314 |
Administration, Scope, and Application — 18.3.5 Power Cable and Conductor Electrical Tests Test Type* No |
media_required |
| 315 |
KU000315 |
Administration, Scope, and Application — 19.3.1 Cable Tray Visual Inspections No |
media_required |
| 316 |
KU000316 |
Administration, Scope, and Application — 19.3.3 Lubrication |
media_required |
| 317 |
KU000317 |
Administration, Scope, and Application — 19.3.1 Cable Tray Visual Inspections No |
media_required |
| 318 |
KU000318 |
Administration, Scope, and Application — 19.3.1 Cable Tray Visual Inspections No |
media_required |
| 319 |
KU000319 |
Administration, Scope, and Application — 21.2 Frequency of Maintenance |
media_required |
| 320 |
KU000320 |
Administration, Scope, and Application — 21.3.2.1 Low-Voltage Ground-Fault Protection Systems Visual Inspections Test Type* No |
media_required |
| 321 |
KU000321 |
Administration, Scope, and Application — 21.3.2.2 Low-Voltage Ground-Fault Protection System Cleaning Test Type* No |
media_required |
| 322 |
KU000322 |
Administration, Scope, and Application — 21.3.2.5 Low-Voltage Ground-Fault Protection System Electrical Testing Test Type* No |
no_media_needed |
| 323 |
KU000323 |
Administration, Scope, and Application — 21.3.3.1 Medium-Voltage Ground-Fault Protection Systems Visual Inspections Test Type* No |
no_media_needed |
| 324 |
KU000324 |
Administration, Scope, and Application — 21.3.3.4 Medium-Voltage Ground-Fault Protection System Mechanical Servicing Test Type* No |
media_required |
| 325 |
KU000325 |
Administration, Scope, and Application — 21.3.2.1 Low-Voltage Ground-Fault Protection Systems Visual Inspections Test Type* No |
media_required |
| 326 |
KU000326 |
Administration, Scope, and Application — 21.3.2.2 Low-Voltage Ground-Fault Protection System Cleaning Test Type* No |
no_media_needed |
| 327 |
KU000327 |
Administration, Scope, and Application — 21.3.2.5 Low-Voltage Ground-Fault Protection System Electrical Testing Test Type* No |
no_media_needed |
| 328 |
KU000328 |
Administration, Scope, and Application — 21.3.3.2 Medium-Voltage Ground-Fault Protection System Cleaning Test Type* No |
no_media_needed |
| 329 |
KU000329 |
Administration, Scope, and Application — 22.2 Frequency of Maintenance |
media_required |
| 330 |
KU000330 |
Administration, Scope, and Application — 22.3.6.1* Maintenance Program |
media_required |
| 331 |
KU000331 |
Administration, Scope, and Application — 24.3.1 Wiring Device Visual Inspections No |
media_required |
| 332 |
KU000332 |
Administration, Scope, and Application — 24.3.3 Lubrication |
no_media_needed |
| 333 |
KU000333 |
Administration, Scope, and Application — 24.3.5 Wiring Device Electrical Tests No |
no_media_needed |
| 334 |
KU000334 |
Administration, Scope, and Application — 24.3.2 Wiring Device Cleaning Test Type* No |
no_media_needed |
| 335 |
KU000335 |
Administration, Scope, and Application — 24.3.5 Wiring Device Electrical Tests No |
media_required |
| 336 |
KU000336 |
Administration, Scope, and Application — 3.6 shall be performed in accordance with the frequencies specified in25 |
media_required |
| 337 |
KU000337 |
Administration, Scope, and Application — 25.3.1 UPS Visual Inspections Test Type* No |
no_media_needed |
| 338 |
KU000338 |
Administration, Scope, and Application — 25.3.2 UPS Cleaning Test Type* No |
no_media_needed |
| 339 |
KU000339 |
Administration, Scope, and Application — 25.3.4 UPS Mechanical Servicing Test Type* No |
media_required |
| 340 |
KU000340 |
Administration, Scope, and Application — 25.3.5 UPS Electrical Tests Test Type* No |
no_media_needed |
| 341 |
KU000341 |
Administration, Scope, and Application — 25.3.6.2.1 System Test Conditions |
media_required |
| 342 |
KU000342 |
Administration, Scope, and Application — 25.3.6.2.2.2 Voltage regulation and frequency stability shall be compared to the manufacturer’s specifications |
no_media_needed |
| 343 |
KU000343 |
Administration, Scope, and Application — 25.3.1 UPS Visual Inspections Test Type* No |
no_media_needed |
| 344 |
KU000344 |
Administration, Scope, and Application — 25.3.2 UPS Cleaning Test Type* No |
no_media_needed |
| 345 |
KU000345 |
Administration, Scope, and Application — 25.3.4 UPS Mechanical Servicing Test Type* No |
media_required |
| 346 |
KU000346 |
Administration, Scope, and Application — 25.3.5 UPS Electrical Tests Test Type* No |
media_required |
| 347 |
KU000347 |
Administration, Scope, and Application — 27.3.1 Rotating Equipment Visual Inspections No |
media_required |
| 348 |
KU000348 |
Administration, Scope, and Application — 27.3.4 Mechanical Servicing No |
no_media_needed |
| 349 |
KU000349 |
Administration, Scope, and Application — 27.3.5 Rotating Equipment Electrical Tests Test Type* No |
media_required |
| 350 |
KU000350 |
Administration, Scope, and Application — 27.3.1 Rotating Equipment Visual Inspections No |
media_required |
| 351 |
KU000351 |
Administration, Scope, and Application — 27.3.4 Mechanical Servicing No |
media_required |
| 352 |
KU000352 |
Administration, Scope, and Application — 27.3.5 Rotating Equipment Electrical Tests Test Type* No |
no_media_needed |
| 353 |
KU000353 |
Administration, Scope, and Application — 27.3.5 Rotating Equipment Electrical Tests Test Type* No |
media_required |
| 354 |
KU000354 |
Administration, Scope, and Application — 28.3 shall be performed in accordance with Table 9 |
media_required |
| 355 |
KU000355 |
Administration, Scope, and Application — 28.3.1 Motor Control Equipment Visual Inspections Test Type* No |
no_media_needed |
| 356 |
KU000356 |
Administration, Scope, and Application — 28.3.4 Motor Control Equipment Mechanical Servicing No |
no_media_needed |
| 357 |
KU000357 |
Administration, Scope, and Application — 28.3.1 Motor Control Equipment Visual Inspections Test Type* No |
no_media_needed |
| 358 |
KU000358 |
Administration, Scope, and Application — 28.3.1 Motor Control Equipment Visual Inspections Test Type* No |
no_media_needed |
| 359 |
KU000359 |
Administration, Scope, and Application — 28.3.5 Motor Control Equipment Electrical Tests Test Type* No |
no_media_needed |
| 360 |
KU000360 |
Administration, Scope, and Application — 29.2 Frequency of Maintenance |
media_required |
| 361 |
KU000361 |
Administration, Scope, and Application — 29.3.1.2 Portable equipment and flexible cord sets (extension cords) that remain connected once they are put in place and are not |
media_required |
| 362 |
KU000362 |
Administration, Scope, and Application — 29.3.4 Mechanical Servicing |
media_required |
| 363 |
KU000363 |
Administration, Scope, and Application — 30.3 shall be performed in accordance with Table 9 |
media_required |
| 364 |
KU000364 |
Administration, Scope, and Application — 30.3.1 PV System Visual Inspections No |
no_media_needed |
| 365 |
KU000365 |
Administration, Scope, and Application — 30.3.5 PV System Electrical Tests No |
media_required |
| 366 |
KU000366 |
Administration, Scope, and Application — 30.4.2* A label that identifies the highest internal dc voltage shall be affixed to combiners, disconnects, and other enclosures |
media_required |
| 367 |
KU000367 |
Administration, Scope, and Application — 30.3.1 PV System Visual Inspections No |
media_required |
| 368 |
KU000368 |
Administration, Scope, and Application — 30.3.3 Lubrication |
no_media_needed |
| 369 |
KU000369 |
Administration, Scope, and Application — 30.4.1* The equipment owner shall ensure that supporting documentation, including the following, is available: • (1) System desi |
media_required |
| 370 |
KU000370 |
Administration, Scope, and Application — 30.4.2* A label that identifies the highest internal dc voltage shall be affixed to combiners, disconnects, and other enclosures |
media_required |
| 371 |
KU000371 |
Administration, Scope, and Application — 30.3.1 PV System Visual Inspections No |
media_required |
| 372 |
KU000372 |
Administration, Scope, and Application — 30.3.5 PV System Electrical Tests No |
media_required |
| 373 |
KU000373 |
Administration, Scope, and Application — 31.3.1 Wind Power Electric Systems and Associated Equipment Visual Inspections and Mechanical Tests No |
no_media_needed |
| 374 |
KU000374 |
Administration, Scope, and Application — 31.3.5 Wind Power Electric Systems and Associated Equipment Electrical Tests No |
no_media_needed |
| 375 |
KU000375 |
Administration, Scope, and Application — 31.3.1 Wind Power Electric Systems and Associated Equipment Visual Inspections and Mechanical Tests No |
no_media_needed |
| 376 |
KU000376 |
Administration, Scope, and Application — 32.1.1* This chapter identifies maintenance requirements and applies to all flow and traditional battery energy storage systems |
media_required |
| 377 |
KU000377 |
Administration, Scope, and Application — 32.3.1 Battery ESS Visual Inspections No |
no_media_needed |
| 378 |
KU000378 |
Administration, Scope, and Application — 32.3.1 Battery ESS Visual Inspections No |
media_required |
| 379 |
KU000379 |
Administration, Scope, and Application — 32.4 Documentation |
media_required |
| 380 |
KU000380 |
Administration, Scope, and Application — 32.2 Maintenance Intervals Test to be Performed Equipment Condition Assessment Condition 1 Condition 2 Condition 3 Battery pe |
no_media_needed |
| 381 |
KU000381 |
Administration, Scope, and Application — 32.3.1 Battery ESS Visual Inspections No |
media_required |
| 382 |
KU000382 |
Administration, Scope, and Application — 33.3 shall be performed in accordance with Table 9 |
media_required |
| 383 |
KU000383 |
Administration, Scope, and Application — 33.3.1.1 Electric Vehicle Power Transfer System Equipment Visual Inspections No |
no_media_needed |
| 384 |
KU000384 |
Administration, Scope, and Application — 33.4.2 The following supporting documentation shall be available for maintenance: • (1) Mechanical drawings (mounting and struc |
media_required |
| 385 |
KU000385 |
Administration, Scope, and Application — 33.3.1.1 Electric Vehicle Power Transfer System Equipment Visual Inspections No |
no_media_needed |
| 386 |
KU000386 |
Administration, Scope, and Application — 34.1.2 This chapter does not apply to pools, fountains, and similar installations located at one- and two-family dwellings, sto |
media_required |
| 387 |
KU000387 |
Administration, Scope, and Application — 34.3.2 Cleaning |
no_media_needed |
| 388 |
KU000388 |
Administration, Scope, and Application — 34.3.5 Public Pools, Fountains, and Similar Installation Electrical Tests Test Type* No |
media_required |
| 389 |
KU000389 |
Administration, Scope, and Application — 34.3.1 Public Pools, Fountains, and Similar Installation Visual Inspections No |
media_required |
| 390 |
KU000390 |
Administration, Scope, and Application — 34.3.4 Public Pools, Fountains, and Similar Installation Mechanical Servicing No |
no_media_needed |
| 391 |
KU000391 |
Administration, Scope, and Application — 35.2 Frequency of Maintenance |
media_required |
| 392 |
KU000392 |
Administration, Scope, and Application — 35.3.2 Protective Relay Cleaning Test Type* No |
media_required |
| 393 |
KU000393 |
Administration, Scope, and Application — 35.3.5 Protective Relay Electrical Tests Test Type* No |
media_required |
| 394 |
KU000394 |
Administration, Scope, and Application — 35.3.5 Protective Relay Electrical Tests Test Type* No |
media_required |
| 395 |
KU000395 |
Administration, Scope, and Application — 35.3.2 Protective Relay Cleaning Test Type* No |
media_required |
| 396 |
KU000396 |
Administration, Scope, and Application — 35.3.5 Protective Relay Electrical Tests Test Type* No |
media_required |
| 397 |
KU000397 |
Administration, Scope, and Application — 35.3.5 Protective Relay Electrical Tests Test Type* No |
media_required |
| 398 |
KU000398 |
Administration, Scope, and Application — 36.2 Maintenance Intervals Equipment Condition Assessme Battery Technology Test to be Performed Condition 1 Condition 2 Inspe |
media_required |
| 399 |
KU000399 |
Administration, Scope, and Application — 36.3.1 Stationary Standby Batteries Visual Inspections No |
no_media_needed |
| 400 |
KU000400 |
Administration, Scope, and Application — 36.4 Documentation |
media_required |